Accident Report Detail
Accident: 202064010 - Employee Overcome By Carbon Monoxide And Drowns
Accident: 202064010 -- Report ID: 0420100 -- Event Date: 05/08/1996 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
106964851 | 05/16/1996 | 3731 | Castings, Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
106964844 | 05/16/1996 | 3731 | Wm. C. Ellis & Sons Iron Works, | ||||
Employee #1 was assigned to remove approximately 12 in. of water from the bow compartment of a barge. The pump that was normally used from the deck level was out of service; instead, he was told to use a smaller gasoline-powered pump, which had to be placed inside the bow area. Employee #1, who remained in the compartment during the operation, became unconscious from exposure to carbon monoxide. He then fell into the water and drowned. The accident occurred at a barge holding area with maintenance and repair activities. | |||||||
Keywords:
barge, ventilation, work rules, inhalation, air contamination, exhaust fumes, fall, drown, poisoning, carbon monoxide
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 106964851 | Fatality | Asphyxia | Helpers, mechanics and repairers | |||
2 | 106964844 | Occupation Not Listed |