Accident: 201992039 - Employee Electrocuted When Excavator Boom Hits Power Line

Accident: 201992039 -- Report ID: 0950411 -- Event Date: 09/16/2005
InspectionOpen DateSICEstablishment Name
30939081309/16/20051611The Ashton Company Inc., Contractors And Engineers
On September 16, 2005, Employee #1, a foreman, was at a site where a 350L Caterpillar excavator was lifting a four-cycle Mikasa rammer out of an excavation. The rammer was connected to the knuckle of the excavator bucket with a 20 ft-long metal choker. The boom of the excavator contacted the overhead power lines and, when Employee #1 reached for the rammer, he was electrocuted.
Keywords: clearance, overhead power line, boom, work rules, electrocuted, struck against, construction, elec circ part--misc, excavator
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street New project or new addition $1,000,000 to $5,000,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 309390813 Fatality Electric Shock Supervisors, material moving equipment operators FallDist:
FallHt:
Cause: Trenching, installing pipe
FatCause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.