Accident: 201954351 - Employee Is Killed When Struck By Falling Trench Shield

Accident: 201954351 -- Report ID: 0522000 -- Event Date: 10/17/2005
InspectionOpen DateSICEstablishment Name
30941410010/18/20051611Sunesis Construction Co.
On October 17, 2005, an excavating company was using a Kebelco 480 excavator to set in place a steel trench shield panel (10-ft-wide by 24-ft-long by 8-in.-thick) as an end plate for the trench box system in a 24-ft-deep excavation. The employer had not determined the weight of the shield and had no information about the capacity of the 0.375-in. chain that was utilized to lift the shield. The operator lifted the shield with the chain attached at one point on the excavator, and the other end attached to one point in the center of the shield. The operator then carried the shield down a 9 degree slope and stopped near the excavation. While swinging the shield to position it, the chain broke. The shield then struck Employee #1, who was working near the excavation. He was killed.
Keywords: chain, excavation, trench box, installing, overloaded, suspended load, trench, excavator, falling object
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street Alteration or rehabilitation $50,000 to $250,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 309414100 Fatality Other Construction trades, n.e.c. FallDist:
FallHt:
Cause: Excavation
FatCause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.