Accident: 201856788 - Employee Is Decapitated By Pot Lid

Accident: 201856788 -- Report ID: 0452110 -- Event Date: 09/06/2006
InspectionOpen DateSICEstablishment Name
31010283509/07/20061799Special Coatings Llc
Employee #1 was standing on a ladder on the side of 8-ton sandblasting pot using a claw hammer to loosen the 12-ft, 20-lb lid on top of the pot. The pot was pressurized to 140 psi and contained coal slag which was used as the sandblasting agent. The lid was held in place by 5 bolts and tightening handles. As Employee #1 loosened the lid, a sudden release of air pressure and slag occurred. The lid was blasted upward and Employee #1 fell backward to the ground. Employee #1 was killed when he was decapitated either by the lid, or by being blown back from the pot and striking the frame of the hopper over the pot. His head was found approximately 153 ft from the pot.
Keywords: air pressure, head, sand pot, bolt, struck by, flying object, decapitated, sandblasting, hopper
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Tower, tank, storage elevator Alteration or rehabilitation $250,000 to $500,000 120 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 310102835 Fatality Other Occupation not reported FallDist:
FallHt:
Cause: Exterior masonry
FatCause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.