Accident: 201770948 - Two Employees Burned And One Injured In Explosion

Accident: 201770948 -- Report ID: 0213900 -- Event Date: 03/23/2000
InspectionOpen DateSICEstablishment Name
30271434003/23/20002834Ganes Chemical
Three chemical operators were loading an intermediate pharmacological product from FIBC drums into a vacuum drier. The product was wet with residual heptane. After loading the first drum into the drier, a static discharge occurred inside the drier and ignited the heptane vapors. Employees #1 and #2 received 2nd and 3rd degree burns to the face, head, hands, and forearms. Employee #3 was knocked off a flight of stairs and received minor contusions. Employees #1 and #2 were hospitalized. Further investigation revealed that there was insufficient nitrogen in the drier and this allowed the vapor and oxygen mixture to reach the flammable range and ignite.
Keywords: burn, head, machinist, forearm, explosion, heptane, face, hand
Employee # Inspection Age Sex Degree Nature Occupation
1 302714340 Hospitalized injury Burn/Scald(Heat) Separating, filtering & clarifying mach. operators
2 302714340 Non Hospitalized injury Bruise/Contus/Abras Separating, filtering & clarifying mach. operators
3 302714340 Hospitalized injury Burn/Scald(Heat) Separating, filtering & clarifying mach. operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.