Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201700101 - Employee Killed When Crushed Inside Chipper

Accident: 201700101 -- Report ID: 1054115 -- Event Date: 08/07/1997
InspectionOpen DateSICEstablishment Name
30128479008/08/19972411Boardman Chip Co Inc
At approximately 9:00 a.m. on August 7, 1997, Employee #1, of the Boardman Chip Co., Inc., was performing maintenance on a ring debarker machine. He and a coworker were inside the debarker feed roll sprocket area to troubleshoot and to inspect the cause of equipment failure. None of the energy sources was locked or tagged out, nor had safety pins been installed to prevent unintended movement. For some reason, the electrical power shut down. The air released, causing an upper and a lower sprocket to come together, pinning Employee #1. He was transported to the hospital, where he died.
Keywords: maintenance, pinned, work rules, lockout, caught between, chipper, crushed, sprocket, logging
Employee # Inspection Age Sex Degree Nature Occupation
1 301284790 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close