Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201635042 - Employee Receives Burns And Inhalation Injury From Ammonia

Accident: 201635042 -- Report ID: 1054191 -- Event Date: 03/21/2005
InspectionOpen DateSICEstablishment Name
30874251903/21/20055181Pyramid Breweries Inc
On March 21, 2005, Employee #1, a maintenance worker, was performing routine preventive maintenance on an ammonia refrigeration system. He intended to drain oil from the system, but due to confusion, he attached his ratchet wrench to an ammonia fitting. The escaping ammonia caused chemical burns to Employee #1's right hand and forearm, and his lungs were irritated. He was hospitalized.
Keywords: lung, ammonia, venting, inhalation, refrigerant, chemical burn, hand tool, refrigerator, hand
Employee # Inspection Age Sex Degree Nature Occupation
1 308742519 Hospitalized injury Burn(Chemical) Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close