Accident Report Detail
Accident: 201622016 - Employee Is Injured In Fall From Lift
Accident: 201622016 -- Report ID: 1054116 -- Event Date: 03/25/2006 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
309690519 | 03/27/2006 | 1521 | Rogue Pacific Construction Co Llc | ||||
On March 25, 2006, Employee #1 was in a boom lift removing siding from the third story of a residence. The lift's guard rails on the side facing the home had been removed previously by the employer and foreman. Employee #1 repositioned the lift such that the unguarded portion faced away from the structure. When he tripped on siding material that had been removed, he fell off the open side. Employee #1 was hospitalized for a compound fracture of his lower left leg (both tibia and fibula). | |||||||
Keywords:
fracture, guardrail, demolition, work rules, tripped, fall, fall protection, elevated work plat, aerial lift, leg
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 309690519 | Hospitalized injury | Fracture | Supervisors; carpenters and related workers |