Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201580123 - One Employee Killed And One Injured When Ramp Flipped Over

Accident: 201580123 -- Report ID: 1032300 -- Event Date: 02/22/2000
InspectionOpen DateSICEstablishment Name
30118827202/22/20004491Crowley Marine Services, Inc.
A barge being tied up struck a ramp puncturing one of the ramp's three floatation tanks. The floatation tank slowly filled with water. As it filled the center of buoyancy and center of gravity moved in opposite directions until the imbalance was sufficient to overcome the shore-side weight of the ramp and the ramp flipped over. Two employees were on the ramp at the time it flipped. Employee #1 was recovered from the water after about 10 minutes and suffered permanent brain damage. Employee #2 was recovered from the water after 30 to 40 minutes and was declared dead about one hour after his removal from the water. A redesign of the ramp by a Registered Professional Engineer approximately one year prior to the accident reduced the ability of the ramp to resist overturning.
Keywords: barge, asphyxiated, ramp, collision, drown, overturn
Employee # Inspection Age Sex Degree Nature Occupation
1 301188272 Hospitalized injury Asphyxia Longshore equipment operators
2 301188272 Fatality Asphyxia Longshore equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close