Accident Report Detail
Accident: 201487709 - Employee Is Injured When Two Forklifts Collide
Accident: 201487709 -- Report ID: 0950622 -- Event Date: 05/30/2005 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
301123097 | 06/14/2005 | 5141 | Albertson'S Vacaville Distribution Center #8795 | ||||
On May 30, 2005, Employee #1, working at a grocery wholesale distribution center, was operating a stand-up forklift when he collided with a sit-down forklift being operated by a coworker. Employee #1 sustained a crushed right foot and was hospitalized. Both employees had full-time employment status with the company. Employee #1's forklift was double pallet jack-6,000 lbs capacity Yale model with Serial Number A803N09032U and Equipment Number 8795-EQP-FT-23-98. The coworker's forklift was a sit down lift-5,000 lbs capacity Yale model with Serial Number E108V09522V and Equipment Number 8795-EQP-FT-23-98. | |||||||
Keywords:
ind trk operator, work rules, collision, industrial truck, struck by, foot, inattention
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 301123097 | Hospitalized injury | Fracture | Occupation not reported |