Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201404035 - Electric Shock - Contact With Overhead Line Thru Boom

Accident: 201404035 -- Report ID: 0552651 -- Event Date: 05/31/2000
InspectionOpen DateSICEstablishment Name
12710938706/01/20001622Ec Korneffel Co
Employees were using a crane to move a concrete barrier. The crane contacted a 7600-volt overhead power line, electrocuting an employee who was holding the sling supporting the barrier.
Keywords: overhead power line, electrical, boom, crane boom, electrocuted, e c, crane
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Bridge Alteration or rehabilitation $1,000,000 to $5,000,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 127109387 Fatality Electric Shock Construction laborers FallDist:
FallHt:
Cause: Placing bridge girders and beams
FatCause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close