Accident Report Detail
Accident: 201363249 - One Employee Is Killed, Four Others Are Injured In Explosion
Accident: 201363249 -- Report ID: 0419400 -- Event Date: 05/03/2008 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
311415145 | 05/05/2008 | 7699 | Hydrochem Industrial Services, Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
311414544 | 05/05/2008 | 1541 | M-Co, Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
311415145 | 05/05/2008 | 7699 | Hydrochem Industrial Services, Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
311414544 | 05/05/2008 | 1541 | M-Co, Inc. | ||||
On May 3, 2008, Employees #1, #2, #3, #4, and #5 were restarting the recovery boiler under a partial-natural-draft. The power boiler was not online at the time. The boiler exploded, and Employee #1 was blown over a standard guard railing on the South side of the sixth floor. He fell down some 25 ft on a scaffold staging. He died from blunt force trauma to the chest. His injuries included lacerations to his both lungs, diaphragm, liver, and thoracic aorta. Employees #2, #3, #4 were burned, and they were hospitalized. Employee #5 sustained sprain and strain of his ankle and was not hospitalized. | |||||||
Keywords:
lung, boiler, laceration, burn, chest, construction, liver, fall, sprain, scaffold
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Powerplant | Maintenance or repair | $250,000 to $500,000 | 10 | X | |||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 311415145 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | FallDist: FallHt: Cause: FatCause: |
||
2 | 311414544 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | FallDist: FallHt: Cause: Fireproofing FatCause: Fire/explosion |
||
3 | 311414544 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | FallDist: FallHt: Cause: Fireproofing FatCause: Fire/explosion |
||
4 | 311415145 | Non Hospitalized injury | Strain/Sprain | Occupation not reported | FallDist: FallHt: Cause: FatCause: |
||
5 | 311414544 | Fatality | Burn/Scald(Heat) | Occupation not reported | FallDist: FallHt: Cause: Fireproofing FatCause: Fire/explosion |