Accident: 201360674 - Telecom Worker Is Killed In Fall From Tree

Accident: 201360674 -- Report ID: 0419400 -- Event Date: 07/21/1998
InspectionOpen DateSICEstablishment Name
30103622407/22/19984841Wireless One
A telecommunications worker had removed a wireless cable television antenna from a tree and was descending the tree using an Arbor-Plex 12.7-millimeter-diameter climbing rope (with a braided polyester outer jacket and a polyolefin fiber core) and a climbing saddle. Friction developed in the taut line hitch knot during his decent melted the polyester guard fibers of the rope, causing the rope to fail. The employee fell 9.2 meters to the ground. He was taken to a hospital, where he died a day later.
Keywords: bosun chair, telecom work, rope, equipment failure, tree, fall, fall protection
Employee # Inspection Age Sex Degree Nature Occupation
1 301036224 Fatality Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.