Accident: 201353216 - Employee Is Killed By Chipping Machine

Accident: 201353216 -- Report ID: 0419700 -- Event Date: 08/26/2006
InspectionOpen DateSICEstablishment Name
31002742008/28/20062421Suwanee Lumber Company
Employee #1 was replacing the knives on a chipping machine that had not been locked out. When Employee #1 crawled into the point of operation of the chipping machine, the electric eye sensed his presence and activated the hydraulic clamping devices that normally hold a log in place during the chipping process. These devices crushed Employee #1, and he died from these crushing injuries.
Keywords: chest, lockout, caught between, chipper, point of operation
Employee # Inspection Age Sex Degree Nature Occupation
1 310027420 Fatality Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.