Accident: 201330792 - Employee Is Killed When Crushed By Fork Lift Truck Batter

Accident: 201330792 -- Report ID: 0213600 -- Event Date: 12/01/2004
InspectionOpen DateSICEstablishment Name
30814146412/01/20045812Faculty Student Association,Inc.
On December 1, 2004, Employee #1 an operator of a Yale Electric stand-up counterbalanced forklift truck, finished repositioning a pallet of material at the rear of his truck that was backed up to the loading dock. The forklift began traveling in reverse, making a counterclockwise semi-circle, driving off the dock and overturning. A the time, the forklift operator was in the operator's compartment of the forklift, when the battery on the forklift, which weighed about 1,300 lbs., slid out of its compartment, landing on top of the operator, crushing him to death.
Keywords: battery, loading, dock, crushed, industrial truck, pallet
Employee # Inspection Age Sex Degree Nature Occupation
1 308141464 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.