Accident: 201280153 - Employee Killed In Fall From Beam

Accident: 201280153 -- Report ID: 0418100 -- Event Date: 06/17/1997
InspectionOpen DateSICEstablishment Name
30097037306/19/19971791Shellhouse Steel Erectors Incorporated
Employee #1, an iron worker helper, was assigned to retrieve an air hose that was stored on top of a 13 ft 7 in. high H-beam. He walked out onto the top of the beam, helped gather the hose, and was turning to go back when he lost his balance and fell to the concrete. Employee #1 sustained a ruptured spleen, and was killed.
Keywords: beam, spleen, iron worker, work rules, construction, rupture, fall, fall protection, walking on beam, lost balance
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other building New project or new addition $1,000,000 to $5,000,000 2 14 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 300970373 Fatality Other Occupation not reported FallDist:
FallHt:14
Cause: Erecting structural steel
FatCause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.