Powered by GoogleTranslate

Accident Report Detail

Accident: 201179256 - Employee Falls And Fractures Hip While Repairing Planer

Accident: 201179256 -- Report ID: 0950621 -- Event Date: 04/13/2006
InspectionOpen DateSICEstablishment Name
12583088505/10/20062421Sierra Pacific Industries, Inc.
Employee #1, a planer operator, was repairing the in-feed side of the planer. Employee #1 placed a pipe wrench on the shaft of the planer feed roll, and then placed a pipe over the end of the pipe wrench to get more leverage. He then placed all of his weight on the pipe to turn the shaft. The jaw of the 24-in. pipe wrench broke off. Employee #1 fell approximately 3.5 ft to the floor and fractured his right hip. Employee #1 was hospitalized.
Keywords: fracture, maintenance, planing machine, machine operator, pipe wrench, struck against, walking surface, fall, pipe, hip
Employee # Inspection Age Sex Degree Nature Occupation
1 125830885 Hospitalized injury Fracture Millwrights

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close