Accident: 201149135 - Employee'S Finger Is Amputated When Bolt Breaks
Accident: 201149135 -- Report ID: 0950631 -- Event Date: 05/16/2007 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
309299238 | 09/07/2007 | 3272 | Desa Fmi Llc | ||||
On May 16, 2007, Employee #1, a punch press operator, was operating a Rousselle Punch Press, Model 10 GAC, Serial Number P-20871, in the employer's fabrication department. Employee #1 was removing a stamped part from the die, when the punch press' brake shoe attachment bolt snapped in two, allowing the clutch brake to release and the 800-lb ram to free fall and crush Employee #1's left hand between the dies. Employee #1 suffered crushing injuries to his hand and an amputation of the fourth digit. He was hospitalized for his injuries. | |||||||
Keywords:
die, amputated, finger, machine operator, caught between, crushed, bolt, falling object, punch press, hand
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 309299238 | Hospitalized injury | Amputation | Pressing machine operators |