Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201148103 - Employee Shocked Placing Sign When Crane Hits Power Line

Accident: 201148103 -- Report ID: 0950631 -- Event Date: 05/24/2006
InspectionOpen DateSICEstablishment Name
12390063105/25/20061799Martinez Sign Inc
On May 24, 2006, Employee #1 and his supervisor were using a Dynalift mobile electric crane, model C.82.4.2.77.204, to install an electric CVS sign near a sidewalk. A lanyard was placed inside at the top of the 97 in. tall by 10 ft 10 in. wide sign, and then secured by the crane hook. Employee #1 was situated on a metal ladder, ready to receive the sign and disconnect the hook. The sign was hoisted into place and Employee #1 had grabbed the hook when he received a 6,900 volt phase-to-ground electric shock and was thrown off the ladder. The supervisor had moved the metal basket into a 36 ft high, 12,000-volt phase-to-phase overhead power line, that was 7 ft 8 in. from the middle of the sign, and 8 ft 6 in. from a cell phone tower. The supervisor moved the basket away from the power line. He got down from the truck, where the controls for the boom were, and ran to Employee #1, who was lying on the ground and not breathing. As he got closer, he saw that Employee #1 had a mark on his hand and he smelled something burned. Employee #1 was transported to the hospital, where he was treated for 12 days for conditions related to the electric shock he had suffered. During subsequent interviews, the fire captain indicated that when he arrived, he estimated that the crane boom was approximately 5 ft from the power lines and the supervisor was moving it away. The supervisor told the compliance officer that he had not seen the power lines before the accident.
Keywords: burn, clearance, overhead power line, work rules, struck against, construction, metal ladder, electric shock, advertising sign
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Commercial building New project or new addition $500,000 to $1,000,000 1 12
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 123900631 Hospitalized injury Electric Shock Construction laborers FallDist:
FallHt:
Cause: Installing equipment (HVAC and other)
FatCause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close