Accident: 201147402 - Employee Slips And Falls From Floor Joists

Accident: 201147402 -- Report ID: 0950631 -- Event Date: 10/19/2005
InspectionOpen DateSICEstablishment Name
12595094911/04/20051531Engineered Framing Systems
On October 19, 2005, Employee #1, a carpenter, was on the second floor attaching plywood to joists. He would apply approximately 3 to 4 ft of glue to the joists. He would then lay a sheet of plywood down and nail it in place. He slipped, due to the glue, and fell approximately 15 ft to the floor. He was hospitalized with a punctured lung and two fractured ribs.
Keywords: fracture, lung, joist, glue, carpenter, slip, pelvis, rib, fall, puncture
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Commercial building New project or new addition $1,000,000 to $5,000,000 2 29
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 125950949 Hospitalized injury Puncture Carpenters FallDist:
FallHt:10
Cause: Pouring or installing floor decks
FatCause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close