Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201140985 - Employee Injured When Equipment Fell On Leg

Accident: 201140985 -- Report ID: 0950631 -- Event Date: 03/23/1999
InspectionOpen DateSICEstablishment Name
12024556804/27/19995082Recat
Employee #1 was removing parts from a road grader that was up on blocks. Although the hydraulic pumps had been removed, the mechanical action of the grader's weight resting on a cylinder had caused hydraulic pressure in one of the 24 hydraulic lines. When that line was loosened, it released the pressure on the "wheel lean" mechanism, causing the grader to shift position. The blocks were knocked out, and the grader dropped, catching Employee #1 and resulting in multiple fractures to both his legs. Employee #1 was hospitalized.
Keywords: fracture, grader, repair, blocks, construction, hydraulic cylinder, hydraulic line, crushed, struck by, leg
Employee # Inspection Age Sex Degree Nature Occupation
1 120245568 Hospitalized injury Fracture Heavy equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.