Accident: 201126984 - Employee'S Arm Is Amputated By Machine

Accident: 201126984 -- Report ID: 0950613 -- Event Date: 12/01/2008
InspectionOpen DateSICEstablishment Name
31009496612/01/20084783All West Container Company
At approximately 9:05 a.m. on December 1, 2008, Employee #1, an employee of All West Container Company in South San Francisco, CA, was working on a Maren giant 60 in./70 in. horizontal baler that compacts cardboards into a cube for recycle. He opened a compartment door manually without the use of hand tools in order to access the blockage of cardboard pieces. Employee #1 was manually clearing the blockage from the shoot of the machine, and his right lower arm was pinned on to the cardboard debris that was being compacted below the shoot. The compacting ram was engaged and compacting the cardboard debris horizontally. The compacting ram pinned the debris along with Employee #1's right lower arm, and it was amputated. Employee #1 was hospitalized. The employer failed to ensure that this compactor access covers/doors required the use of hand tools to open, or be interlocked with the ram controls to prevent movement of the ram when the doors are open. The employer did not guard this employee in at least one of the following: (1) By the installation of a point-of-operation guard or cover having the following features: (A) When closed will prevent the entry of any part of an employee's body. (B) Cannot close while any part of an employee's body is within the point-of-operation. (C) Is interlocked in a manner that prevents travel of the ram unless the guard or cover is in place. (D) In itself does not create a shearing or crushing hazard. (2) By deadman controls so located that the operator cannot reach the point of operation while operating the controls. (3) By other means which will positively prevent employees from entering the zone of travel of the ram while it is in operation, or will positively prevent any travel of the ram whenever an employee enters or reaches into the zone of travel of the ram.
Keywords: amputated, deadman control, pinned, forearm, lockout, point of operation, baler, arm, unguarded, ram
Employee # Inspection Age Sex Degree Nature Occupation
1 310094966 Hospitalized injury Amputation Compressing and compacting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close