Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 201125903 - Employee Is Severely Burned In Fire

Accident: 201125903 -- Report ID: 0950613 -- Event Date: 03/02/2006
InspectionOpen DateSICEstablishment Name
30084435403/17/20064953Romic Environmental Technologies
On March 2, 2006, Employee #1, a welder, was torch cutting on top of a 12,000 gallon carbon-steel tank in a hazardous waste treatment, storage, and recycling facility. The tank, which had a cone bottom and was about 28.5 feet above the ground, had previously held solvent contaminated wastewater. An Industrial Scientific Corporation multi-gas monitoring instrument, Model Number 140, Serial Number 0312193-005, equipped with a sampling pump, Serial Number 05120XW-025, and 6.5-foot tubing, entering the tank from an 8-inch top hatch, was used to monitor the atmosphere inside the tank. As Employee #1 was kneeling next to the top hatch of the tank, on the walkway above the tank, torch cutting through the top of the tank, a fire occurred. Flames came out of the top hatch and caught his clothes on fire. Employee #1 was hospitalized approximately six hours later, where he was treated for second and third degree burns on his buttock and perineum area. Employee #1 was wearing a personal fall arrest system to include a body harness and shock absorbing lanyard, which allowed him to reach outside the guarded walkway. The accident investigation revealed that the accident was caused by inadequate preparation of the tank for hot work. Although the tank had been steam cleaned prior to the welding operation, the tank was neither isolated nor purged. Additionally, there was insufficient monitoring of the tank atmosphere. The employer was issued two serious violations, prohibiting their engagement in activities requiring the use of direct air monitoring equipment, as well as welding operations.
Keywords: burn, flammable vapors, buttocks, fire, welder, gas, torch, tank, cutting and burning
Employee # Inspection Age Sex Degree Nature Occupation
1 300844354 Hospitalized injury Burn/Scald(Heat) Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close