Accident: 201100047 - Employee'S Thumb Amputated In V-Belt Of Conveyor

Accident: 201100047 -- Report ID: 0950623 -- Event Date: 07/17/1996
InspectionOpen DateSICEstablishment Name
12017425508/06/19962421Sierra Pacific Industries
Employee #1, a millwright working the swing shift for a large sawmill operator, was opening the guard on the V-belt pulley drive on a conveyor. As Employee #1 put his hand on the belt, an electrician moved the arm of a limit switch that started the V-belt drive motor. Employee #1's right hand thumb was amputated to the first joint. Neither the electrician nor Employee #1 locked out the controls to the motor before working on the piece of equipment.
Keywords: amputated, work rules, caught by, thumb, lockout, millwright, conveyor, v-belt, nip point, communication
Employee # Inspection Age Sex Degree Nature Occupation
1 120174255 Hospitalized injury Amputation Millwrights

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.