Accident: 201075181 - Employee Amputates Two Fingers While Operating Machinery

Accident: 201075181 -- Report ID: 0950632 -- Event Date: 04/27/2010
InspectionOpen DateSICEstablishment Name
31268237005/06/20107363Aerotek
At approximately 2:00 p.m. on April 27, 2010, Employee #1, a spring machine operator, and a coworker were removing a partially manufactured automobile wheel from the mandrel of a metal spinning machine. As Employee #1 completed a spinning operation for a wheel on an S-1 automatic-spinning machine, Model Number A/S 3040, Serial Number 03-736, and the machine stopped, he grabbed a hold of the wheel and started to pull it out of the mandrel. However, the spinning machine was still in production mode and the tailstock automatically reversed, pushing the wheel back into the mandrel and pinching Employee #1's fingers between the edge of the wheel and the mandrel. Emergency services were contacted and Employee #1 was taken to Tri City Medical Center in Oceanside, where he was hospitalized and treated for amputated ring and pinky fingers on his right hand. The incident investigation heard conflicting stories leading up to the accident, but determined that the machine was operating properly. It was determined that either Employee #1 or another worker must have depressed the controls on the machine, causing the tailstock to reverse.
Keywords: amputated, finger, pinned, control lever, machine operator, caught by, caught between
Employee # Inspection Age Sex Degree Nature Occupation
1 312682370 Hospitalized injury Amputation Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.