Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200962868 - Employee Injured When Caught In Steel Rollers Of Extruder

Accident: 200962868 -- Report ID: 0352440 -- Event Date: 06/30/1999
InspectionOpen DateSICEstablishment Name
30279829306/30/19992824Specialty Filaments, Inc.
Employee #1 was removing broken filament threads that had wrapped themselves around the 10 in. steel rollers of a polypropylene extruder machine. He was reaching between the rollers to cut out the scrap material when his arm, which was wet from sweating, brushed against the hot roller and stuck to it. Employee #1's arm, shoulder, and head were pulled into the in-running nip point of the rollers before he managed to pull himself out and fall to the floor. He sustained a fractured collarbone, two fractured ribs, severe lacerations to his right ear and over his right eye, and multiple contusions to his arm, chest, and head. Employee #1 was transported to the Baltimore Shock Trauma Center for treatment.
Keywords: fracture, heat, work rules, collarbone, caught by, roller--mach/part, caught between, mech mat handling, arm, nip point
Employee # Inspection Age Sex Degree Nature Occupation
1 302798293 Hospitalized injury Fracture Miscellaneous textile machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close