Accident: 200901148 - Employee Killed In Trench Cave-In

Accident: 200901148 -- Report ID: 0418400 -- Event Date: 10/08/2002
InspectionOpen DateSICEstablishment Name
30377219810/08/20021711Pitts Plumbing, Llc
Employee #1 and other employees were installing two 2500-gallon tanks to be used as grease traps. They were digging a trench that was approximately 9 feet deep, 7.5 feet wide, and 40 feet long. After digging the trench, Employee #1 went inside the trench with a measuring rod while another employee stayed on top of the surface to use the transit scope with sight glass to take the depth measurement of the trench. Employee #1 started at the west end of the trench and walked to the east end. After taking three readings, the other employee started walking toward the trench. He saw that the asphalt was cracked and yelled for Employee #1 to get out. Employee #1 started running toward the east end of the trench where the excavator was parked, then turned around and was in the process of running toward the west end of the trench. The south wall that was approximately six feet long and one foot wide caved-in, knocking him to the ground. Employee #1 was covered with dirt up to his face. He was transported to a local hospital where he was pronounced dead. The company was not using any protective systems.
Keywords: measuring device, trench, excavator, cave-in, face, tank, asphalt
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Excavation, landfill New project or new addition $1,000,000 to $5,000,000 X
Employee # Inspection Age Sex Degree Nature Occupation
1 303772198 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close