Accident Report Detail
Accident: 200850741 - Employee Killed In Fall Into Elevator Pit
Accident: 200850741 -- Report ID: 0215000 -- Event Date: 11/05/1998 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
300619152 | 11/06/1998 | 7699 | Horizon Elevator Co. | ||||
Employee #1, an elevator maintenance worker, was standing on elevator #3 while he tried to fix elevator #2. As he jumped from elevator #3 to elevator #2, elevator #3 was activated and he became pinned in the raceway piping. Employee #1 then fell into the pit for elevator #2, and was killed. | |||||||
Keywords:
repair, pinned, work rules, lockout, caught between, pit, fall, elevator, elevator shaft
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 300619152 | Fatality | Fracture | Occupation not reported |