Accident: 200840080 - Employee Killed When Exposed To Toxic Gas In Sewer

Accident: 200840080 -- Report ID: 0524530 -- Event Date: 08/08/1996
InspectionOpen DateSICEstablishment Name
30060294308/09/19961623Womack Brothers
Employee #1 and a coworker were assigned to search for a missing plug in one of several manholes in an active sewer system. They opened three manholes, climbed down 12 ft, and used a flashlight to look in the 15 in. pipes. Employee #1 then went into a fourth manhole, where he was overcome by toxic gases. He died several hours later.
Keywords: sewer, vapor, toxic atmosphere, construction, inhalation, chemical vapor, poisoning, toxic fumes, manhole, overexposure
Employee # Inspection Age Sex Degree Nature Occupation
1 300602943 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.