Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200823268 - Two Employees Are Asphyxiated In Confined Space Atmosphere

Accident: 200823268 -- Report ID: 0521400 -- Event Date: 03/09/2006
InspectionOpen DateSICEstablishment Name
30976496704/05/20067699Surface Maintenance Services, Inc.
On March 9, 2006, Employees #1 and #2 were cleaning the inside of a tank that was almost 8 ft deep. The paint stripper being used contained methylene chloride, methanol, and xylene. The vapors were heavier than air and displaced the oxygen at the bottom of the tank. The first employee to enter the tank lost consciousness. The other employee entered the tank to perform a rescue, but he too, lost consciousness. Both employees were rescued and were hospitalized for asphyxia.
Keywords: methyl alcohol, unconsciousness, asphyxiated, confined space, methylene chloride, xylene, cleaning, paint solvent, painter, tank
Employee # Inspection Age Sex Degree Nature Occupation
1 309764967 Hospitalized injury Asphyxia Supervisors; handlers,equip-cleaners,laborers nec
2 309764967 Hospitalized injury Asphyxia Supervisors; handlers,equip-cleaners,laborers nec

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close