Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200811107 - Electric Shock - Contact With Overhead Line Thru Boom

Accident: 200811107 -- Report ID: 0627400 -- Event Date: 04/26/1997
InspectionOpen DateSICEstablishment Name
11032721004/29/19971771Thomas Hicks Construction Inc.
An employee who had been leased from Allied Staffing was electrocuted when a crane boom contacted an overhead power line.
Keywords: overhead power line, electrical, boom, crane boom, electrocuted, e gi ia, crane
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Powerline, transmission line Other Under $50,000 18 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 110327210 Fatality Electric Shock Occupation not reported FallDist:
FallHt:
Cause: Demolition
FatCause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close