Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200810232 - Truck Driver Killed When Struck By Flying Object

Accident: 200810232 -- Report ID: 0627400 -- Event Date: 04/01/1997
InspectionOpen DateSICEstablishment Name
30057354004/02/19971389Circle Iii Services, Inc.
Employee #1, a truck driver, used a Tulsa winch mounted onto an autocar flatbed pole truck to pick up a float that had dropped to the ground after an attempt to attach it to a freightliner tractor. After the task had been completed, the winch truck was moved back into its parking spot. The winch's power take-off (PTO) had not been disengaged, and the line became bound up and broke the Clevis block. It flew into the cab through the back window, striking and killing Employee #1.
Keywords: blocks, hoist, oil well servicing, struck by, entangled, flying object, flatbed truck, winch, power take-off, truck driver
Employee # Inspection Age Sex Degree Nature Occupation
1 300573540 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close