Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200774867 - Employee Killed When Scaffold Pole Contacts Power Line

Accident: 200774867 -- Report ID: 0134000 -- Event Date: 12/08/2007
InspectionOpen DateSICEstablishment Name
31159682912/08/20071761Dave'S Construction
On December 8, 2007, Employer #1 and a coworker were erecting a pole section of a pump jack scaffold to continue siding a condominium under construction in Lowell, MA. They lost control of the pole section and it struck an approximately 7,600-volt powerline running adjacent to the construction site. Employee #1 was electrocuted and was pronounced dead at the scene. His coworker suffered only minor injuries.
Keywords: clearance, overhead power line, work rules, electrocuted, struck against, construction, pump jack scaffold, metal pole, elec circ part--misc, lost control
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Single family or duplex dwelling New project or new addition $1,000,000 to $5,000,000 3 40 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 311596829 Fatality Electric Shock Occupation not reported FallDist:
FallHt:
Cause: Installing metal siding
FatCause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.