Accident: 200741650 - Employee Dies After Being Asphyxiated In Storm Drain Manhole

Accident: 200741650 -- Report ID: 0213100 -- Event Date: 07/14/2004
InspectionOpen DateSICEstablishment Name
30753439607/14/20041629Joy Developers Inc.
On July 14, 2004, Employee #1 entered a 12-foot deep concrete storm drain manhole to retrieve a plastic bucket that was obstructing an outflow pipe. The employee lost consciousness moments after entry. Further investigation revealed that no confined space entry procedures were utilized and the area contained less than 13.7 percent oxygen. Employee #1 died on August 14, 2004.
Keywords: oxygen deficiency, unconsciousness, asphyxiated, confined space, work rules, manhole
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Sewer/water treatment plant Maintenance or repair $500,000 to $1,000,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 307534396 Fatality Asphyxia Occupation not reported FallDist:
FallHt:
Cause: Trenching, installing pipe
FatCause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.