Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200690162 - Employee Killed When Forklift Truck Overturned

Accident: 200690162 -- Report ID: 0112600 -- Event Date: 06/25/1998
InspectionOpen DateSICEstablishment Name
30050540106/26/19985713Post Road Carpet West
Employee #1 was crushed and killed when his forklift truck overturned.
Keywords: ind trk operator, work rules, caught between, crushed, industrial truck, mech mat handling, motor vehicle, overturn
Employee # Inspection Age Sex Degree Nature Occupation
1 300505401 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close