Accident Report Detail
Accident: 200650257 - Five Employees Exposed To Sulfur Dioxide
Accident: 200650257 -- Report ID: 0521100 -- Event Date: 02/09/1999 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
300483708 | 02/09/1999 | 2621 | Weyerhaeuser Company | ||||
During a maintenance procedure, between 22,000 and 33,000 gallons of calcium bisulfite cooking acid was released from a digester. Employees #1 through #5 and 12 coworkers were exposed to sulfur dioxide, which is released when calcium bisulfite cooking acid is exposed to air. Employees #1 through #5 sustained chemical burns and were hospitalized; the 12 coworkers were evaluated and released. | |||||||
Keywords:
maintenance, caustic, unsecured, chemical reaction, sulfur dioxide, chemical burn, skin, accidental discharge, chemical
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 300483708 | Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | |||
2 | 300483708 | Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | |||
3 | 300483708 | Hospitalized injury | Burn(Chemical) | Plumbers, pipefitters and steamfitters | |||
4 | 300483708 | Hospitalized injury | Burn(Chemical) | Plumbers, pipefitters and steamfitters | |||
5 | 300483708 | Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations |