Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200642122 - Employee Killed When Struck By Falling Culvert

Accident: 200642122 -- Report ID: 0627700 -- Event Date: 10/25/2001
InspectionOpen DateSICEstablishment Name
30364666510/25/20011623Earth Engineering Div. Bryan Adair
Employee #1 was helping to set a culvert as part of an underground storm drain system. Employee #1 was standing next to the concrete box culvert that was partly suspended by 2 legs of the 4 legs of a sling. The culvert would not match-up with the previous culvert. The box broke and fell into Employee #1. The pry bar Employee #1 was using to nudge the box into final position was knocked into his chest breaking his sternum bone and causing the bone to pierce his heart. Employee #1 was killed.
Keywords: chest, heart, rigging, drain pipe, struck by, falling object, pry bar, puncture
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Sewer/water treatment plant New project or new addition $500,000 to $1,000,000 5 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 303646665 Fatality Puncture Occupation not reported FallDist:
FallHt:
Cause: Trenching, installing pipe
FatCause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close