Accident: 200621233 - Employee Struck And Killed By Falling Roll Of Paper

Accident: 200621233 -- Report ID: 0454716 -- Event Date: 11/20/2000
InspectionOpen DateSICEstablishment Name
30400078911/21/20002671Vacumet Corporation
Employee #1 was lowering a lift on which was resting a 3,900 lb roll of metallized paper. The lift would not return to floor level, so he had taken a chuck from under the roll and was down on his hands and knees, trying to find out what was wrong. The paper rolling machine was continuing to roll paper; when it completed a cycle, the rolling arms struck the metallized roll and knocked it off the lift. The roll landed on Employee #1, who died of asphyxia.
Keywords: asphyxiated, unsecured, work rules, struck against, paper roll, industrial truck, mech mat handling, struck by, falling object, mech malfunction
Employee # Inspection Age Sex Degree Nature Occupation
1 304000789 Fatality Asphyxia Rolling machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.