Accident: 200620383 - Employee Killed When Vapors Ignite

Accident: 200620383 -- Report ID: 0454712 -- Event Date: 06/23/1999
InspectionOpen DateSICEstablishment Name
30248445607/09/19992851The Egyptian Laquer Manufacturing Company
Employee #1 and a coworker were pouring nitrocellulose from a 99 lb fiber drum into the top of a 3,000-gal tank when the flammable vapors ignited. Employee #1 died of burns sustained in the fire. The drum and the steel tank were not bonded together during the pouring process. The steel tank contained a flammable solvent, and nitrocellulose is also flammable. A static charge may have been source of ignition for the fire.
Keywords: burn, static electricity, flammable liquid, flammable vapors, work rules, fire, combustible liquid, chemical
Employee # Inspection Age Sex Degree Nature Occupation
1 302484456 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.