Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200612026 - Employees Are Injured In Rack Collapse

Accident: 200612026 -- Report ID: 0111700 -- Event Date: 11/15/2005
InspectionOpen DateSICEstablishment Name
30695284711/15/20051711Ouellette Plumbing & Heating Corp.
On November 15, 2005, Employees #1 through #6 were loading a Unistrut rack with copper pipe of varying sizes. The rack collapsed Employee #1, who was then hospitalized with fractures. Employees #2 trough #6 sustained various injuries during the rescue of Employee #1. The rack had been improperly constructed in three ways: (1) single through-bolts were used to assemble some of the horizontal and vertical members within the rack, instead of "T" or gusset connections, as specified by the rack component manufacturer; using the single bolts allowed the connections to rotate around the bolt, (2) the horizontal braces were connected with single bolts, instead of "T" or gusset connections, as specified by the rack component manufacturer; using the single bolts allowed the connections to rotate around the bolt, and (3) diagonal braces were not used to stabilize the frames.
Keywords: collapse, equipment failure, bolt, brace, pipe, storage rack, struck by, storage area
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other building New project or new addition $5,000,000 to $20,000,000 4
Employee # Inspection Age Sex Degree Nature Occupation
1 306952847 Non Hospitalized injury Strain/Sprain Occupation not reported
2 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
3 306952847 Non Hospitalized injury Strain/Sprain Occupation not reported
4 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
5 306952847 Hospitalized injury Fracture Occupation not reported
6 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.