Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200611556 - Employee Killed In Fall From Roof Decking

Accident: 200611556 -- Report ID: 0111700 -- Event Date: 09/16/2003
InspectionOpen DateSICEstablishment Name
30456307509/16/20031791Roberto'S Steel Erectors, Inc.
At approximately 9:50 a.m. on September 16, 2003, Employee #1 was working as part of a three-person crew laying decking on a roof. Several bays of decking had already been completed when he opened another bundle and started to lay out the sheets. He was apparently taking a new sheet off the stack and was sliding it forward when he slipped and fell on the bundle. Employee #1 then slipped off the bundle and fell approximately 33 ft to the ground. He was killed. Approximately 1.25 inches of rain had fallen overnight and the steel joists on which Employee #1 was standing were likely still wet. Employee #1 and his coworkers were wearing harnesses with lanyards attached, but they were not tied off. The other crew members, the foreman, and the company's owner thought they did not need to tie off since they were working within a Controlled Decking Zone (CDZ). However, no CDZ had been established according to the standard, although CDZ stanchions and rope were on the ground less than 40 ft from where Employee #1 fell. The foreman and the owner explained that they had not yet brought the stanchions up to the roof and put them in place. They were not aware that a CDZ could not be used at that site because the roof area where the decking was being done exceeded 30 ft. Additionally, there was more than 3,000 sq ft of unsecured decking on the roof.
Keywords: roof, work rules, slip, construction, fall, fall protection, slippery surface, tie-off, work surface
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Commercial building New project or new addition $5,000,000 to $20,000,000 1 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 304563075 Fatality Fracture Occupation not reported FallDist:
FallHt:33
Cause: Installation Of Decking-Initial Laying Deck (Incl
FatCause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.