Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200556629 - Employee Is Electrocuted In Ship Under Construction

Accident: 200556629 -- Report ID: 0625700 -- Event Date: 07/14/2011
InspectionOpen DateSICEstablishment Name
31477206207/14/20113731Ingalls Shipbuilding
On July 14, 2011, Employee #1, an electrical strapper, was working alone in a compartment of the Naval vessel LPD-23 under construction at Ingalls Shipyard. He was fastening metal straps to electrical wire bundles along the walls and ceiling of the compartments. A ladder was provided for Employee #1 to reach the ceiling; however, he did not use it due to obstructions in his work area. Apparently, Employee #1 climbed onto piping to reach the ceiling and stepped on a metal cover that protected a 110/440 volt solenoid-activated pilot valve for the AFFF fire suppression system. Employee #1 was found dead of electrocution. There were no witnesses to the incident. The metal cover was marked "DANGER HIGH VOLTAGE"; it was found dislodged after the incident.
Keywords: cover, shipyard, work rules, electrocuted, ladder, ship, pipe, unstable position
Employee # Inspection Age Sex Degree Nature Occupation
1 314772062 Fatality Electric Shock Electrical and electronic equipment assemblers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close