Accident Report Detail
Accident: 200554038 - Employee Killed In Fall
Accident: 200554038 -- Report ID: 0625700 -- Event Date: 09/08/2005 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
309079192 | 09/09/2005 | 1799 | Scaffolding Rental And Erection Services, Llc | ||||
At approximately 7:45 a.m. on September 8, 2005, Employee #1 was dismantling scaffolding which was erected on a flat roof. Employee #1 had personal fall protection equipment; however, he did not have his lanyard secured. Employee #1 lost his balance, fell 67 feet to the concrete, and was killed. | |||||||
Keywords:
dismantling, ppe, struck against, fall, fall protection, lost balance, work surface, scaffold
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Other building | New project or new addition | $50,000 to $250,000 | 5 | 67 | X | ||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 309079192 | Fatality | Other | Helpers, construction trades | FallDist: FallHt:67 Cause: Exterior carpentry FatCause: Fall from/with scaffold |