Accident: 200553386 - Three Employees Struck By High Pressure Water Are Injured

Accident: 200553386 -- Report ID: 0625700 -- Event Date: 07/02/2004
InspectionOpen DateSICEstablishment Name
30759751807/06/20048741Lonestar Deepwater
InspectionOpen DateSICEstablishment Name
30759617107/06/20041629Weatherford U.S., Inc.
InspectionOpen DateSICEstablishment Name
30759589207/06/20041623All Seas Usa, Inc
Three employees were preparing a 30-in. crude line for hydrostatic testing. Once the line was pressurized to 1,750 pounds per square inch for 1 hour, a failure occurred at the weld that was attached to the 4-in. bushing. Employees #1, #2, and #3 were seriously injured when pressure and water were released from the line. All three employees were hospitalized.
Keywords: pipeline, struck by, pressure release, water, equipment failure, fracture, installing, trench, pressure piping
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Pipeline New project or new addition $20,000,000 and over
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 307597518 Hospitalized injury Other Occupation not reported FallDist:
FallHt:
Cause:
FatCause:
2 307596171 Hospitalized injury Other Occupation not reported FallDist:
FallHt:
Cause: Trenching, installing pipe
FatCause: Other
3 307595892 Hospitalized injury Fracture Occupation not reported FallDist:
FallHt:
Cause: Trenching, installing pipe
FatCause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.