Accident: 200551125 - Employee Killed When Struck By Falling Crane Boom

Accident: 200551125 -- Report ID: 0625700 -- Event Date: 09/28/1999
InspectionOpen DateSICEstablishment Name
30307647509/28/19991799The Spartan Group
InspectionOpen DateSICEstablishment Name
30307649109/28/19991531Air Products And Chemicals, Inc.
InspectionOpen DateSICEstablishment Name
30307648309/28/19991731Merit Electrical & Instrumentation Corp
On September 28, 1999, Employee #3, a 19-year-old electrical instrument helper with Merit Electrical and Instrumentation Corporation (MEI), was at an Air Products facility construction site in Geismar, LA. That morning a contractor had positioned a 50-ton Lorain LRT 400 series hydraulic crane in an open area that consisted of compacted fill material. This was the only location that the crane could situated because the receiving area for the equipment was very close to the property border. MEI had set up a work bench and its personnel were using it as a staging area for work conducted in the general area. Employee #1 was at the work bench, with his back to the crane, cutting Unistrut metal framing for electrical installations. The crane was moving large sections of piping to a new location when it overturned and Employee #1 was struck by the falling crane boom. He was killed. The crane's outriggers were set but matting was placed only under the northwest outrigger pad because of buried piping in the area. At the start of the construction project, Air Products was responsible for clearing the site and having fill material brought in. The site was originally swamp and large amounts of fill had been brought in and compacted prior to commencing construction.
Keywords: mech mat handling, hydraulic crane, crane boom, struck by, unstable soil, overturn, construction, unstable position
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Refinery New project or new addition $1,000,000 to $5,000,000 100 X
Employee # Inspection Age Sex Degree Nature Occupation
1 303076475 Occupation Not Listed
2 303076491 Occupation Not Listed
3 303076483 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.