Accident: 200540995 - Employee Killed When Struck On Head By Falling Ice
Accident: 200540995 -- Report ID: 0317500 -- Event Date: 02/11/2004 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
306959958 | 02/11/2004 | 1799 | M Pw Industrial Services Inc. | ||||
On February 11, 2004, Employee #1 was unclogging a 20-in. intake pipe that was inside another 48-in. line. A large chunk of ice slid down the larger pipe and hit the employee on the back of his head and killed him. | |||||||
Keywords:
fracture, head, confined space, ppe, struck by, falling object
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Sewer/water treatment plant | Maintenance or repair | $50,000 to $250,000 | 1 | 15 | X | ||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 306959958 | Fatality | Fracture | Occupation not reported | FallDist: FallHt: Cause: Temporary work (buildings, facilities) FatCause: Struck by falling object/projectile |