Accident: 200540128 - Employee Dies Of Burns After Iron Dust Explosion And Fire

Accident: 200540128 -- Report ID: 0317500 -- Event Date: 12/24/1996
InspectionOpen DateSICEstablishment Name
30037933601/03/19973399Penn Steel Corporation
On December 24, 1996, Employee #1 was using a skip hoist and monorail system to raise a 1,000 lb, 55 gallon drum of metal iron dust. The drum overturned and dust spilled outside the separation system and throughout the work area, covering both Employee #1 and an operating forklift. The dust exploded, igniting Employee #1's clothes. He sustained burns over 90 percent of his body, and died on December 29, 1996.
Keywords: burn, dust, unsecured, drum, fire, explosion, air contamination, spill, combustible dust, overturn
Employee # Inspection Age Sex Degree Nature Occupation
1 300379336 Fatality Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.