Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200515435 - Employee Dies During Tree Felling

Accident: 200515435 -- Report ID: 0552700 -- Event Date: 09/01/2011
InspectionOpen DateSICEstablishment Name
31584188209/01/20110783The Davey Tree Expert Company
On September 1, 2011, Employee #1 and a coworker were felling tree limbs on a sugar maple tree at a rural residence. The tree had been damaged by a storm. While Employee #1 was located approximately 20 to 25 feet above the ground, standing on the last limb to be cut, the limb broke about 7 feet down from where he was standing. He was also tied-off to this portion of the limb, which caused Employee #1 to become entangled with the limb as they fell. Employee #1 struck the ground with the limb landing on top of his torso and another portion striking his head. Employee #1 died as a result of his injuries.
Keywords: fracture, head, tree felling, pinned, torso, crushed, fall protection, struck by, elevated work plat, tree trimming
Employee # Inspection Age Sex Degree Nature Occupation
1 315841882 Fatality Other Timber cutting and logging occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close