Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200513844 - Employee Electrocuted When Boom Contacts Power Line

Accident: 200513844 -- Report ID: 0552700 -- Event Date: 09/07/2005
InspectionOpen DateSICEstablishment Name
30936216809/08/20051623Infrasource Underground Construction Services Llc
At approximately 7:50 a.m. on September 7, 2005, Employee #1 was part of a three-man crew installing earth anchors at the base of an overhead power line pole. He inserted a metal anchor rod into the anchor wrench that was attached to the boom on a digger/derrick truck. The boom was also in contact with an energized 14,400-volt overhead line. Employee #1 was electrocuted.
Keywords: boom truck, derrick truck, overhead power line, power line worker, work rules, electrocuted, struck against, construction, elec circ part--misc
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other building Alteration or rehabilitation $1,000,000 to $5,000,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 309362168 Fatality Electric Shock Electrical power installers and repairers FallDist:
FallHt:
Cause: Temporary work (buildings, facilities)
FatCause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.