Accident: 200460400 - Two Employees Injured When Block Wall Collapses

Accident: 200460400 -- Report ID: 0111400 -- Event Date: 04/23/1999
InspectionOpen DateSICEstablishment Name
30206334204/23/19991542Chapel Hill Developement Corporation
Employees #1 and #2 were pumping concrete behind a concrete block wall that was being used as formwork. The wall collapsed, trapping them underneath it. Employees #1 and #2 sustained serious multiple fractures and contusions, and were transported by ambulance to Boston University Medical Center in South Boston. The wall was inadequately braced.
Keywords: concrete form work, fracture, wall, collapse, unsecured, pinned, work rules, construction, bracing, contusion
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Multi-family dwelling Alteration or rehabilitation $250,000 to $500,000 5
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 302063342 Hospitalized injury Fracture Brickmasons and stonemasons FallDist:
FallHt:
Cause: Pouring concrete foundations and walls
FatCause: Collapse of structure
2 302063342 Hospitalized injury Other Construction laborers FallDist:
FallHt:
Cause: Pouring concrete foundations and walls
FatCause: Collapse of structure

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.